Battery Age Verification
Check battery serial number to determine age and assess lifecycle stage.
Visual Inspection
Identify raised positive terminals (a sign of sulfation).
Look for overwatering indicators like case pitting or water run marks.
Inspect cables for rot or damage at base connectors.
Performance Testing
Measure voltage and specific gravity to ensure each cell is functioning properly.
Light Cleaning
Remove surface debris and buildup to maintain clean, efficient operation.
Cable & Connector Repair
Repair or replace damaged cables and intercell connectors to prevent electrical failures.